diff --git a/lib/services/systemd.c b/lib/services/systemd.c index 95d00b4515..adc2616bd8 100644 --- a/lib/services/systemd.c +++ b/lib/services/systemd.c @@ -1,1005 +1,1008 @@ /* * Copyright 2012-2021 the Pacemaker project contributors * * The version control history for this file may have further details. * * This source code is licensed under the GNU Lesser General Public License * version 2.1 or later (LGPLv2.1+) WITHOUT ANY WARRANTY. */ #include #include #include #include #include #include #include #include #include #include static void invoke_unit_by_path(svc_action_t *op, const char *unit); #define BUS_NAME "org.freedesktop.systemd1" #define BUS_NAME_MANAGER BUS_NAME ".Manager" #define BUS_NAME_UNIT BUS_NAME ".Unit" #define BUS_PATH "/org/freedesktop/systemd1" static inline DBusMessage * systemd_new_method(const char *method) { crm_trace("Calling: %s on " BUS_NAME_MANAGER, method); return dbus_message_new_method_call(BUS_NAME, BUS_PATH, BUS_NAME_MANAGER, method); } /* * Functions to manage a static DBus connection */ static DBusConnection* systemd_proxy = NULL; static inline DBusPendingCall * systemd_send(DBusMessage *msg, void(*done)(DBusPendingCall *pending, void *user_data), void *user_data, int timeout) { return pcmk_dbus_send(msg, systemd_proxy, done, user_data, timeout); } static inline DBusMessage * systemd_send_recv(DBusMessage *msg, DBusError *error, int timeout) { return pcmk_dbus_send_recv(msg, systemd_proxy, error, timeout); } /*! * \internal * \brief Send a method to systemd without arguments, and wait for reply * * \param[in] method Method to send * * \return Systemd reply on success, NULL (and error will be logged) otherwise * * \note The caller must call dbus_message_unref() on the reply after * handling it. */ static DBusMessage * systemd_call_simple_method(const char *method) { DBusMessage *msg = systemd_new_method(method); DBusMessage *reply = NULL; DBusError error; /* Don't call systemd_init() here, because that calls this */ CRM_CHECK(systemd_proxy, return NULL); if (msg == NULL) { crm_err("Could not create message to send %s to systemd", method); return NULL; } dbus_error_init(&error); reply = systemd_send_recv(msg, &error, DBUS_TIMEOUT_USE_DEFAULT); dbus_message_unref(msg); if (dbus_error_is_set(&error)) { crm_err("Could not send %s to systemd: %s (%s)", method, error.message, error.name); dbus_error_free(&error); return NULL; } else if (reply == NULL) { crm_err("Could not send %s to systemd: no reply received", method); return NULL; } return reply; } static gboolean systemd_init(void) { static int need_init = 1; // https://dbus.freedesktop.org/doc/api/html/group__DBusConnection.html if (systemd_proxy && dbus_connection_get_is_connected(systemd_proxy) == FALSE) { crm_warn("Connection to System DBus is closed. Reconnecting..."); pcmk_dbus_disconnect(systemd_proxy); systemd_proxy = NULL; need_init = 1; } if (need_init) { need_init = 0; systemd_proxy = pcmk_dbus_connect(); } if (systemd_proxy == NULL) { return FALSE; } return TRUE; } static inline char * systemd_get_property(const char *unit, const char *name, void (*callback)(const char *name, const char *value, void *userdata), void *userdata, DBusPendingCall **pending, int timeout) { return systemd_proxy? pcmk_dbus_get_property(systemd_proxy, BUS_NAME, unit, BUS_NAME_UNIT, name, callback, userdata, pending, timeout) : NULL; } void systemd_cleanup(void) { if (systemd_proxy) { pcmk_dbus_disconnect(systemd_proxy); systemd_proxy = NULL; } } /* * end of systemd_proxy functions */ /*! * \internal * \brief Check whether a file name represents a manageable systemd unit * * \param[in] name File name to check * * \return Pointer to "dot" before filename extension if so, NULL otherwise */ static const char * systemd_unit_extension(const char *name) { if (name) { const char *dot = strrchr(name, '.'); if (dot && (!strcmp(dot, ".service") || !strcmp(dot, ".socket") || !strcmp(dot, ".mount") || !strcmp(dot, ".timer") || !strcmp(dot, ".path"))) { return dot; } } return NULL; } static char * systemd_service_name(const char *name) { if (name == NULL) { return NULL; } if (systemd_unit_extension(name)) { return strdup(name); } return crm_strdup_printf("%s.service", name); } static void systemd_daemon_reload_complete(DBusPendingCall *pending, void *user_data) { DBusError error; DBusMessage *reply = NULL; unsigned int reload_count = GPOINTER_TO_UINT(user_data); dbus_error_init(&error); if(pending) { reply = dbus_pending_call_steal_reply(pending); } if (pcmk_dbus_find_error(pending, reply, &error)) { crm_err("Could not issue systemd reload %d: %s", reload_count, error.message); dbus_error_free(&error); } else { crm_trace("Reload %d complete", reload_count); } if(pending) { dbus_pending_call_unref(pending); } if(reply) { dbus_message_unref(reply); } } static bool systemd_daemon_reload(int timeout) { static unsigned int reload_count = 0; DBusMessage *msg = systemd_new_method("Reload"); reload_count++; CRM_ASSERT(msg != NULL); systemd_send(msg, systemd_daemon_reload_complete, GUINT_TO_POINTER(reload_count), timeout); dbus_message_unref(msg); return TRUE; } /*! * \internal * \brief Set an action result based on a method error * * \param[in] op Action to set result for * \param[in] error Method error */ static void set_result_from_method_error(svc_action_t *op, const DBusError *error) { op->rc = PCMK_OCF_UNKNOWN_ERROR; op->status = PCMK_EXEC_ERROR; if (strstr(error->name, "org.freedesktop.systemd1.InvalidName") || strstr(error->name, "org.freedesktop.systemd1.LoadFailed") || strstr(error->name, "org.freedesktop.systemd1.NoSuchUnit")) { if (pcmk__str_eq(op->action, "stop", pcmk__str_casei)) { crm_trace("Masking systemd stop failure (%s) for %s " "because unknown service can be considered stopped", error->name, crm_str(op->rsc)); op->rc = PCMK_OCF_OK; op->status = PCMK_EXEC_DONE; return; } op->rc = PCMK_OCF_NOT_INSTALLED; op->status = PCMK_EXEC_NOT_INSTALLED; } crm_err("DBus request for %s of systemd unit %s for resource %s failed: %s", op->action, op->agent, crm_str(op->rsc), error->message); } /*! * \internal * \brief Extract unit path from LoadUnit reply, and execute action * * \param[in] reply LoadUnit reply * \param[in] op Action to execute (or NULL to just return path) * * \return DBus object path for specified unit if successful (only valid for * lifetime of \p reply), otherwise NULL */ static const char * execute_after_loadunit(DBusMessage *reply, svc_action_t *op) { const char *path = NULL; DBusError error; /* path here is not used other than as a non-NULL flag to indicate that a * request was indeed sent */ if (pcmk_dbus_find_error((void *) &path, reply, &error)) { if (op != NULL) { set_result_from_method_error(op, &error); } dbus_error_free(&error); } else if (!pcmk_dbus_type_check(reply, NULL, DBUS_TYPE_OBJECT_PATH, __func__, __LINE__)) { if (op != NULL) { op->rc = PCMK_OCF_UNKNOWN_ERROR; op->status = PCMK_EXEC_ERROR; + crm_err("Could not load systemd unit %s for %s: " + "DBus reply has unexpected type", op->agent, op->id); + } else { + crm_err("Could not load systemd unit: " + "DBus reply has unexpected type"); } - crm_err("Could not load systemd unit %s for %s: " - "systemd reply has unexpected type", op->agent, op->id); } else { dbus_message_get_args (reply, NULL, DBUS_TYPE_OBJECT_PATH, &path, DBUS_TYPE_INVALID); } if (op != NULL) { if (path != NULL) { invoke_unit_by_path(op, path); } else if (!(op->synchronous)) { op->rc = PCMK_OCF_UNKNOWN_ERROR; op->status = PCMK_EXEC_ERROR; services__finalize_async_op(op); } } return path; } /*! * \internal * \brief Execute a systemd action after its LoadUnit completes * * \param[in] pending If not NULL, DBus call associated with LoadUnit request * \param[in] user_data Action to execute */ static void loadunit_completed(DBusPendingCall *pending, void *user_data) { DBusMessage *reply = NULL; svc_action_t *op = user_data; crm_trace("LoadUnit result for %s arrived", op->id); // Grab the reply if (pending != NULL) { reply = dbus_pending_call_steal_reply(pending); } // The call is no longer pending CRM_LOG_ASSERT(pending == op->opaque->pending); services_set_op_pending(op, NULL); // Execute the desired action based on the reply execute_after_loadunit(reply, user_data); if (reply != NULL) { dbus_message_unref(reply); } } /*! * \internal * \brief Execute a systemd action, given the unit name * * \param[in] arg_name Unit name (possibly shortened, i.e. without ".service") * \param[in] op Action to execute (if NULL, just get the object path) * \param[out] path If non-NULL and \p op is NULL or synchronous, where to * store DBus object path for specified unit * * \return Standard Pacemaker return code (for NULL \p op, pcmk_rc_ok means unit * was found; for synchronous actions, pcmk_rc_ok means unit was * executed, with the actual result stored in \p op; for asynchronous * actions, pcmk_rc_ok means action was initiated) * \note It is the caller's responsibility to free the return value if non-NULL. */ static int invoke_unit_by_name(const char *arg_name, svc_action_t *op, char **path) { DBusMessage *msg; DBusMessage *reply = NULL; DBusPendingCall *pending = NULL; char *name = NULL; if (!systemd_init()) { if (op != NULL) { op->rc = PCMK_OCF_UNKNOWN_ERROR; op->status = PCMK_EXEC_ERROR; } return ENOTCONN; } /* Create a LoadUnit DBus method (equivalent to GetUnit if already loaded), * which makes the unit usable via further DBus methods. * * * * * */ msg = systemd_new_method("LoadUnit"); CRM_ASSERT(msg != NULL); // Add the (expanded) unit name as the argument name = systemd_service_name(arg_name); CRM_LOG_ASSERT(dbus_message_append_args(msg, DBUS_TYPE_STRING, &name, DBUS_TYPE_INVALID)); free(name); if ((op == NULL) || op->synchronous) { // For synchronous ops, wait for a reply and extract the result const char *unit = NULL; int rc = pcmk_rc_ok; reply = systemd_send_recv(msg, NULL, (op? op->timeout : DBUS_TIMEOUT_USE_DEFAULT)); dbus_message_unref(msg); unit = execute_after_loadunit(reply, op); if (unit == NULL) { rc = ENOENT; if (path != NULL) { *path = NULL; } } else if (path != NULL) { *path = strdup(unit); if (*path == NULL) { rc = ENOMEM; } } if (reply != NULL) { dbus_message_unref(reply); } return rc; } // For asynchronous ops, initiate the LoadUnit call and return pending = systemd_send(msg, loadunit_completed, op, op->timeout); if (pending == NULL) { op->rc = PCMK_OCF_UNKNOWN_ERROR; op->status = PCMK_EXEC_ERROR; dbus_message_unref(msg); return ECOMM; } // LoadUnit was successfully initiated op->rc = PCMK_OCF_UNKNOWN; op->status = PCMK_EXEC_PENDING; services_set_op_pending(op, pending); dbus_message_unref(msg); return pcmk_rc_ok; } /*! * \internal * \brief Compare two strings alphabetically (case-insensitive) * * \param[in] a First string to compare * \param[in] b Second string to compare * * \return 0 if strings are equal, -1 if a < b, 1 if a > b * * \note Usable as a GCompareFunc with g_list_sort(). * NULL is considered less than non-NULL. */ static gint sort_str(gconstpointer a, gconstpointer b) { if (!a && !b) { return 0; } else if (!a) { return -1; } else if (!b) { return 1; } return strcasecmp(a, b); } GList * systemd_unit_listall(void) { int nfiles = 0; GList *units = NULL; DBusMessageIter args; DBusMessageIter unit; DBusMessageIter elem; DBusMessage *reply = NULL; if (systemd_init() == FALSE) { return NULL; } /* " \n" \ " \n" \ " \n" \ */ reply = systemd_call_simple_method("ListUnitFiles"); if (reply == NULL) { return NULL; } if (!dbus_message_iter_init(reply, &args)) { crm_err("Could not list systemd unit files: systemd reply has no arguments"); dbus_message_unref(reply); return NULL; } if (!pcmk_dbus_type_check(reply, &args, DBUS_TYPE_ARRAY, __func__, __LINE__)) { crm_err("Could not list systemd unit files: systemd reply has invalid arguments"); dbus_message_unref(reply); return NULL; } dbus_message_iter_recurse(&args, &unit); for (; dbus_message_iter_get_arg_type(&unit) != DBUS_TYPE_INVALID; dbus_message_iter_next(&unit)) { DBusBasicValue value; const char *match = NULL; char *unit_name = NULL; char *basename = NULL; if(!pcmk_dbus_type_check(reply, &unit, DBUS_TYPE_STRUCT, __func__, __LINE__)) { crm_warn("Skipping systemd reply argument with unexpected type"); continue; } dbus_message_iter_recurse(&unit, &elem); if(!pcmk_dbus_type_check(reply, &elem, DBUS_TYPE_STRING, __func__, __LINE__)) { crm_warn("Skipping systemd reply argument with no string"); continue; } dbus_message_iter_get_basic(&elem, &value); if (value.str == NULL) { crm_debug("ListUnitFiles reply did not provide a string"); continue; } crm_trace("DBus ListUnitFiles listed: %s", value.str); match = systemd_unit_extension(value.str); if (match == NULL) { // This is not a unit file type we know how to manage crm_debug("ListUnitFiles entry '%s' is not supported as resource", value.str); continue; } // ListUnitFiles returns full path names, we just want base name basename = strrchr(value.str, '/'); if (basename) { basename = basename + 1; } else { basename = value.str; } if (!strcmp(match, ".service")) { // Service is the "default" unit type, so strip it unit_name = strndup(basename, match - basename); } else { unit_name = strdup(basename); } nfiles++; units = g_list_prepend(units, unit_name); } dbus_message_unref(reply); crm_trace("Found %d manageable systemd unit files", nfiles); units = g_list_sort(units, sort_str); return units; } gboolean systemd_unit_exists(const char *name) { /* Note: Makes a blocking dbus calls * Used by resources_find_service_class() when resource class=service */ return invoke_unit_by_name(name, NULL, NULL) == pcmk_rc_ok; } #define METADATA_FORMAT \ "\n" \ "\n" \ "\n" \ " 1.1\n" \ " \n" \ " %s\n" \ " \n" \ " systemd unit file for %s\n" \ " \n" \ " \n" \ " \n" \ " \n" \ " \n" \ " \n" \ " \n" \ " \n" \ " \n" \ "\n" static char * systemd_unit_metadata(const char *name, int timeout) { char *meta = NULL; char *desc = NULL; char *path = NULL; if (invoke_unit_by_name(name, NULL, &path) == pcmk_rc_ok) { /* TODO: Worth a making blocking call for? Probably not. Possibly if cached. */ desc = systemd_get_property(path, "Description", NULL, NULL, NULL, timeout); } else { desc = crm_strdup_printf("Systemd unit file for %s", name); } meta = crm_strdup_printf(METADATA_FORMAT, name, desc, name); free(desc); free(path); return meta; } /*! * \internal * \brief Determine result of method from reply * * \param[in] reply Reply to start, stop, or restart request * \param[in] op Action that was executed */ static void process_unit_method_reply(DBusMessage *reply, svc_action_t *op) { DBusError error; /* The first use of error here is not used other than as a non-NULL flag to * indicate that a request was indeed sent */ if (pcmk_dbus_find_error((void *) &error, reply, &error)) { set_result_from_method_error(op, &error); dbus_error_free(&error); } else if (!pcmk_dbus_type_check(reply, NULL, DBUS_TYPE_OBJECT_PATH, __func__, __LINE__)) { crm_warn("DBus request for %s of %s succeeded but " "return type was unexpected", op->action, crm_str(op->rsc)); op->rc = PCMK_OCF_OK; op->status = PCMK_EXEC_DONE; } else { const char *path = NULL; dbus_message_get_args(reply, NULL, DBUS_TYPE_OBJECT_PATH, &path, DBUS_TYPE_INVALID); crm_debug("DBus request for %s of %s using %s succeeded", op->action, crm_str(op->rsc), path); op->rc = PCMK_OCF_OK; op->status = PCMK_EXEC_DONE; } } /*! * \internal * \brief Process the completion of an asynchronous unit start, stop, or restart * * \param[in] pending If not NULL, DBus call associated with request * \param[in] user_data Action that was executed */ static void unit_method_complete(DBusPendingCall *pending, void *user_data) { DBusMessage *reply = NULL; svc_action_t *op = user_data; crm_trace("Result for %s arrived", op->id); // Grab the reply if (pending != NULL) { reply = dbus_pending_call_steal_reply(pending); } // The call is no longer pending CRM_LOG_ASSERT(pending == op->opaque->pending); services_set_op_pending(op, NULL); // Determine result and finalize action process_unit_method_reply(reply, op); services__finalize_async_op(op); if (reply != NULL) { dbus_message_unref(reply); } } #define SYSTEMD_OVERRIDE_ROOT "/run/systemd/system/" /* When the cluster manages a systemd resource, we create a unit file override * to order the service "before" pacemaker. The "before" relationship won't * actually be used, since systemd won't ever start the resource -- we're * interested in the reverse shutdown ordering it creates, to ensure that * systemd doesn't stop the resource at shutdown while pacemaker is still * running. * * @TODO Add start timeout */ #define SYSTEMD_OVERRIDE_TEMPLATE \ "[Unit]\n" \ "Description=Cluster Controlled %s\n" \ "Before=pacemaker.service pacemaker_remote.service\n" \ "\n" \ "[Service]\n" \ "Restart=no\n" // Temporarily use rwxr-xr-x umask when opening a file for writing static FILE * create_world_readable(const char *filename) { mode_t orig_umask = umask(S_IWGRP | S_IWOTH); FILE *fp = fopen(filename, "w"); umask(orig_umask); return fp; } static void create_override_dir(const char *agent) { char *override_dir = crm_strdup_printf(SYSTEMD_OVERRIDE_ROOT "/%s.service.d", agent); int rc = pcmk__build_path(override_dir, 0755); if (rc != pcmk_rc_ok) { crm_warn("Could not create systemd override directory %s: %s", override_dir, pcmk_rc_str(rc)); } free(override_dir); } static char * get_override_filename(const char *agent) { return crm_strdup_printf(SYSTEMD_OVERRIDE_ROOT "/%s.service.d/50-pacemaker.conf", agent); } static void systemd_create_override(const char *agent, int timeout) { FILE *file_strm = NULL; char *override_file = get_override_filename(agent); create_override_dir(agent); /* Ensure the override file is world-readable. This is not strictly * necessary, but it avoids a systemd warning in the logs. */ file_strm = create_world_readable(override_file); if (file_strm == NULL) { crm_err("Cannot open systemd override file %s for writing", override_file); } else { char *override = crm_strdup_printf(SYSTEMD_OVERRIDE_TEMPLATE, agent); int rc = fprintf(file_strm, "%s\n", override); free(override); if (rc < 0) { crm_perror(LOG_WARNING, "Cannot write to systemd override file %s", override_file); } fflush(file_strm); fclose(file_strm); systemd_daemon_reload(timeout); } free(override_file); } static void systemd_remove_override(const char *agent, int timeout) { char *override_file = get_override_filename(agent); int rc = unlink(override_file); if (rc < 0) { // Stop may be called when already stopped, which is fine crm_perror(LOG_DEBUG, "Cannot remove systemd override file %s", override_file); } else { systemd_daemon_reload(timeout); } free(override_file); } /*! * \internal * \brief Parse result of systemd status check * * Set a status action's exit status and execution status based on a DBus * property check result, and finalize the action if asynchronous. * * \param[in] name DBus interface name for property that was checked * \param[in] state Property value * \param[in] userdata Status action that check was done for */ static void parse_status_result(const char *name, const char *state, void *userdata) { svc_action_t *op = userdata; crm_trace("Resource %s has %s='%s'", crm_str(op->rsc), name, crm_str(state)); if (pcmk__str_eq(state, "active", pcmk__str_none)) { op->rc = PCMK_OCF_OK; op->status = PCMK_EXEC_DONE; } else if (pcmk__str_eq(state, "reloading", pcmk__str_none)) { op->rc = PCMK_OCF_OK; op->status = PCMK_EXEC_DONE; } else if (pcmk__str_eq(state, "activating", pcmk__str_none)) { op->rc = PCMK_OCF_UNKNOWN; op->status = PCMK_EXEC_PENDING; } else if (pcmk__str_eq(state, "deactivating", pcmk__str_none)) { op->rc = PCMK_OCF_UNKNOWN; op->status = PCMK_EXEC_PENDING; } else { op->rc = PCMK_OCF_NOT_RUNNING; op->status = PCMK_EXEC_DONE; } if (!(op->synchronous)) { services_set_op_pending(op, NULL); services__finalize_async_op(op); } } /*! * \internal * \brief Invoke a systemd unit, given its DBus object path * * \param[in] op Action to execute * \param[in] unit DBus object path of systemd unit to invoke */ static void invoke_unit_by_path(svc_action_t *op, const char *unit) { const char *method = NULL; DBusMessage *msg = NULL; DBusMessage *reply = NULL; if (pcmk__str_any_of(op->action, "monitor", "status", NULL)) { DBusPendingCall *pending = NULL; char *state; state = systemd_get_property(unit, "ActiveState", (op->synchronous? NULL : parse_status_result), op, (op->synchronous? NULL : &pending), op->timeout); if (op->synchronous) { parse_status_result("ActiveState", state, op); free(state); } else if (pending == NULL) { // Could not get ActiveState property op->rc = PCMK_OCF_UNKNOWN_ERROR; op->status = PCMK_EXEC_ERROR; services__finalize_async_op(op); } else { services_set_op_pending(op, pending); } return; } else if (pcmk__str_eq(op->action, "start", pcmk__str_none)) { method = "StartUnit"; systemd_create_override(op->agent, op->timeout); } else if (pcmk__str_eq(op->action, "stop", pcmk__str_none)) { method = "StopUnit"; systemd_remove_override(op->agent, op->timeout); } else if (pcmk__str_eq(op->action, "restart", pcmk__str_none)) { method = "RestartUnit"; } else { op->rc = PCMK_OCF_UNIMPLEMENT_FEATURE; op->status = PCMK_EXEC_ERROR; if (!(op->synchronous)) { services__finalize_async_op(op); } return; } crm_trace("Calling %s for unit path %s named %s", method, unit, crm_str(op->rsc)); msg = systemd_new_method(method); CRM_ASSERT(msg != NULL); /* (ss) */ { const char *replace_s = "replace"; char *name = systemd_service_name(op->agent); CRM_LOG_ASSERT(dbus_message_append_args(msg, DBUS_TYPE_STRING, &name, DBUS_TYPE_INVALID)); CRM_LOG_ASSERT(dbus_message_append_args(msg, DBUS_TYPE_STRING, &replace_s, DBUS_TYPE_INVALID)); free(name); } if (op->synchronous) { reply = systemd_send_recv(msg, NULL, op->timeout); dbus_message_unref(msg); process_unit_method_reply(reply, op); if (reply != NULL) { dbus_message_unref(reply); } } else { DBusPendingCall *pending = systemd_send(msg, unit_method_complete, op, op->timeout); dbus_message_unref(msg); if (pending == NULL) { op->rc = PCMK_OCF_UNKNOWN_ERROR; op->status = PCMK_EXEC_ERROR; services__finalize_async_op(op); } else { services_set_op_pending(op, pending); } } } static gboolean systemd_timeout_callback(gpointer p) { svc_action_t * op = p; op->opaque->timerid = 0; crm_warn("%s operation on systemd unit %s named '%s' timed out", op->action, op->agent, op->rsc); op->rc = PCMK_OCF_UNKNOWN_ERROR; op->status = PCMK_EXEC_TIMEOUT; services__finalize_async_op(op); return FALSE; } /*! * \internal * \brief Execute a systemd action * * \param[in] op Action to execute * * \return Standard Pacemaker return code * \retval EBUSY Recurring operation could not be initiated * \retval pcmk_rc_error Synchronous action failed * \retval pcmk_rc_ok Synchronous action succeeded, or asynchronous action * should not be freed (because it already was or is * pending) * * \note If the return value for an asynchronous action is not pcmk_rc_ok, the * caller is responsible for freeing the action. */ int services__execute_systemd(svc_action_t *op) { CRM_ASSERT(op != NULL); if ((op->action == NULL) || (op->agent == NULL)) { op->rc = PCMK_OCF_NOT_CONFIGURED; op->status = PCMK_EXEC_ERROR_FATAL; goto done; } if (!systemd_init()) { op->rc = PCMK_OCF_UNKNOWN_ERROR; op->status = PCMK_EXEC_ERROR; goto done; } crm_debug("Performing %ssynchronous %s op on systemd unit %s named '%s'", (op->synchronous? "" : "a"), op->action, op->agent, crm_str(op->rsc)); if (pcmk__str_eq(op->action, "meta-data", pcmk__str_casei)) { op->stdout_data = systemd_unit_metadata(op->agent, op->timeout); op->rc = PCMK_OCF_OK; op->status = PCMK_EXEC_DONE; goto done; } /* invoke_unit_by_name() should always override these values, which are here * just as a fail-safe in case there are any code paths that neglect to */ op->rc = PCMK_OCF_UNKNOWN_ERROR; op->status = PCMK_EXEC_ERROR; if (invoke_unit_by_name(op->agent, op, NULL) == pcmk_rc_ok) { op->opaque->timerid = g_timeout_add(op->timeout + 5000, systemd_timeout_callback, op); services_add_inflight_op(op); return pcmk_rc_ok; } done: if (op->synchronous) { return (op->rc == PCMK_OCF_OK)? pcmk_rc_ok : pcmk_rc_error; } else { return services__finalize_async_op(op); } }