Page Menu
Home
ClusterLabs Projects
Search
Configure Global Search
Log In
Files
F1841885
No One
Temporary
Actions
View File
Edit File
Delete File
View Transforms
Subscribe
Mute Notifications
Flag For Later
Award Token
Size
76 KB
Referenced Files
None
Subscribers
None
View Options
diff --git a/cts/cts-exec.in b/cts/cts-exec.in
index 7d5a17936f..955701701f 100644
--- a/cts/cts-exec.in
+++ b/cts/cts-exec.in
@@ -1,1254 +1,1264 @@
#!@PYTHON@
""" Regression tests for Pacemaker's pacemaker-execd
"""
__copyright__ = "Copyright 2012-2021 the Pacemaker project contributors"
__license__ = "GNU General Public License version 2 or later (GPLv2+) WITHOUT ANY WARRANTY"
import io
import os
import stat
import sys
import subprocess
import shlex
import shutil
+import tempfile
import time
# Where to find test binaries
# Prefer the source tree if available
BUILD_DIR = "@abs_top_builddir@"
TEST_DIR = sys.path[0]
SBIN_DIR = "@sbindir@"
# Check whether Pacemaker Remote support was built
REMOTE_ENABLED = "@PC_NAME_GNUTLS@" != ""
# File permissions for executable scripts we create
EXECMODE = stat.S_IRUSR | stat.S_IXUSR | stat.S_IRGRP | stat.S_IXGRP | stat.S_IROTH | stat.S_IXOTH
# These values must be kept in sync with include/crm/crm.h
class CrmExit(object):
OK = 0
ERROR = 1
INVALID_PARAM = 2
UNIMPLEMENT_FEATURE = 3
INSUFFICIENT_PRIV = 4
NOT_INSTALLED = 5
NOT_CONFIGURED = 6
NOT_RUNNING = 7
USAGE = 64
DATAERR = 65
NOINPUT = 66
NOUSER = 67
NOHOST = 68
UNAVAILABLE = 69
SOFTWARE = 70
OSERR = 71
OSFILE = 72
CANTCREAT = 73
IOERR = 74
TEMPFAIL = 75
PROTOCOL = 76
NOPERM = 77
CONFIG = 78
FATAL = 100
PANIC = 101
DISCONNECT = 102
SOLO = 103
DIGEST = 104
NOSUCH = 105
QUORUM = 106
UNSAFE = 107
EXISTS = 108
MULTIPLE = 109
OLD = 110
TIMEOUT = 124
MAX = 255
def update_path():
""" Set the PATH environment variable appropriately for the tests """
new_path = os.environ['PATH']
if os.path.exists("%s/cts-exec.in" % TEST_DIR):
print("Running tests from the source tree: %s (%s)" % (BUILD_DIR, TEST_DIR))
# For pacemaker-execd, cts-exec-helper, and pacemaker-remoted
new_path = "%s/daemons/execd:%s" % (BUILD_DIR, new_path)
new_path = "%s/tools:%s" % (BUILD_DIR, new_path) # For crm_resource
# For pacemaker-fenced
new_path = "%s/daemons/fenced:%s" % (BUILD_DIR, new_path)
# For cts-support
new_path = "%s/cts/support:%s" % (BUILD_DIR, new_path)
else:
print("Running tests from the install tree: @CRM_DAEMON_DIR@ (not %s)" % TEST_DIR)
# For cts-exec-helper, cts-support, pacemaker-execd, pacemaker-fenced,
# and pacemaker-remoted
new_path = "@CRM_DAEMON_DIR@:%s" % (new_path)
print('Using PATH="{}"'.format(new_path))
os.environ['PATH'] = new_path
def output_from_command(command):
""" Run a command, and return its standard output. """
test = subprocess.Popen(shlex.split(command), stdout=subprocess.PIPE)
test.wait()
output = test.communicate()[0].decode(sys.stdout.encoding)
return output.split("\n")
class TestError(Exception):
""" Base class for exceptions in this module """
pass
class ExitCodeError(TestError):
""" Exception raised when command exit status is unexpected """
def __init__(self, exit_code):
self.exit_code = exit_code
def __str__(self):
return repr(self.exit_code)
class OutputNotFoundError(TestError):
""" Exception raised when command output does not contain wanted string """
def __init__(self, output):
self.output = output
def __str__(self):
return repr(self.output)
class OutputFoundError(TestError):
""" Exception raised when command output contains unwanted string """
def __init__(self, output):
self.output = output
def __str__(self):
return repr(self.output)
class Test(object):
""" Executor for a single pacemaker-execd regression test """
- def __init__(self, name, description, verbose=0, tls=0, timeout=2, force_wait=0):
+ def __init__(self, name, description, verbose=0, tls=0, timeout=2,
+ force_wait=0, logdir="/tmp"):
+
self.name = name
self.description = description
self.cmds = []
- self.logpath = "/tmp/pacemaker-execd-regression.log"
if tls:
self.daemon_location = "pacemaker-remoted"
else:
self.daemon_location = "pacemaker-execd"
+ self.logpath = os.path.join(logdir, self.daemon_location + ".log")
self.test_tool_location = "cts-exec-helper"
self.verbose = verbose
self.tls = tls
self.timeout = timeout
self.force_wait = force_wait
self.result_txt = ""
self.cmd_tool_output = ""
self.result_exitcode = CrmExit.OK
self.execd_process = None
self.stonith_process = None
self.executed = 0
def __new_cmd(self, cmd, args, exitcode, stdout_match="", no_wait=0, stdout_negative_match="", kill=None):
""" Add a command to be executed as part of this test """
if self.verbose and cmd == self.test_tool_location:
args = args + " -V "
if (cmd == self.test_tool_location) and self.tls:
args = args + " -S "
self.cmds.append(
{
"cmd" : cmd,
"kill" : kill,
"args" : args,
"expected_exitcode" : exitcode,
"stdout_match" : stdout_match,
"stdout_negative_match" : stdout_negative_match,
"no_wait" : no_wait,
"cmd_output" : "",
}
)
def start_environment(self):
""" Prepare the host for running a test """
### make sure we are in full control here ###
cmd = shlex.split("killall -q -9 pacemaker-fenced lt-pacemaker-fenced pacemaker-execd lt-pacemaker-execd cts-exec-helper lt-cts-exec-helper pacemaker-remoted")
test = subprocess.Popen(cmd, stdout=subprocess.PIPE)
test.wait()
additional_args = ""
if self.tls == 0:
self.stonith_process = subprocess.Popen(shlex.split("pacemaker-fenced -s"))
if self.verbose:
additional_args = additional_args + " -V"
self.execd_process = subprocess.Popen(shlex.split("%s %s -l %s"
% (self.daemon_location, additional_args, self.logpath)))
logfile = None
init_time = time.time()
update_time = init_time
while True:
time.sleep(0.1)
if self.force_wait == 0 and logfile == None \
and os.path.exists(self.logpath):
logfile = io.open(self.logpath, 'rt', encoding = "ISO-8859-1")
if self.force_wait == 0 and logfile != None:
for line in logfile.readlines():
if "successfully started" in line:
return
now = time.time()
if self.timeout > 0 and (now - init_time) >= self.timeout:
if self.force_wait == 0:
print("\tDaemon %s doesn't seem to have been initialized within %fs."
"\n\tConsider specifying a longer '--timeout' value."
%(self.daemon_location, self.timeout))
return
if self.verbose and (now - update_time) >= 5:
print("Waiting for %s to be initialized: %fs ..."
%(self.daemon_location, now - init_time))
update_time = now
def clean_environment(self):
""" Clean up the host after running a test """
if self.execd_process:
self.execd_process.terminate()
self.execd_process.wait()
if self.verbose:
print("Daemon output")
logfile = io.open(self.logpath, 'rt', errors='replace')
for line in logfile:
print(line.strip().encode('utf-8', 'replace'))
- os.remove(self.logpath)
if self.stonith_process:
self.stonith_process.terminate()
self.stonith_process.wait()
self.execd_process = None
self.stonith_process = None
def add_sys_cmd(self, cmd, args):
""" Add a simple command to be executed as part of this test """
self.__new_cmd(cmd, args, CrmExit.OK, "")
def add_cmd_check_stdout(self, args, match, no_match=""):
""" Add a command with expected output to be executed as part of this test """
self.__new_cmd(self.test_tool_location, args, CrmExit.OK, match, 0, no_match)
def add_cmd(self, args):
""" Add a cts-exec-helper command to be executed as part of this test """
self.__new_cmd(self.test_tool_location, args, CrmExit.OK, "")
def add_cmd_and_kill(self, kill_proc, args):
""" Add a cts-exec-helper command and system command to be executed as part of this test """
self.__new_cmd(self.test_tool_location, args, CrmExit.OK, "", kill=kill_proc)
def add_expected_fail_cmd(self, args, exitcode=CrmExit.ERROR):
""" Add a cts-exec-helper command to be executed as part of this test and expected to fail """
self.__new_cmd(self.test_tool_location, args, exitcode, "")
def get_exitcode(self):
""" Return the exit status of the last test execution """
return self.result_exitcode
def print_result(self, filler):
""" Print the result of the last test execution """
print("%s%s" % (filler, self.result_txt))
def run_cmd(self, args):
""" Execute a command as part of this test """
cmd = shlex.split(args['args'])
cmd.insert(0, args['cmd'])
if self.verbose:
print("\n\nRunning: "+" ".join(cmd))
test = subprocess.Popen(cmd, stdout=subprocess.PIPE)
if args['kill']:
if self.verbose:
print("Also running: "+args['kill'])
### Typically, the kill argument is used to detect some sort of
### failure. Without yielding for a few seconds here, the process
### launched earlier that is listening for the failure may not have
### time to connect to pacemaker-execd.
time.sleep(2)
subprocess.Popen(shlex.split(args['kill']))
if args['no_wait'] == 0:
test.wait()
else:
return CrmExit.OK
output = test.communicate()[0].decode(sys.stdout.encoding)
args['cmd_output'] = output
if test.returncode != args['expected_exitcode']:
raise ExitCodeError(test.returncode)
if args['stdout_match'] != "" and output.count(args['stdout_match']) == 0:
raise OutputNotFoundError(output)
if args['stdout_negative_match'] != "" and output.count(args['stdout_negative_match']) != 0:
raise OutputFoundError(output)
def set_error(self, step, cmd):
""" Record failure of this test """
msg = "FAILURE - '%s' failed at step %d. Command: %s %s"
self.result_txt = msg % (self.name, step, cmd['cmd'], cmd['args'])
self.result_exitcode = CrmExit.ERROR
def run(self):
""" Execute this test. """
res = 0
i = 1
if self.tls and self.name.count("stonith") != 0:
self.result_txt = "SKIPPED - '%s' - disabled when testing pacemaker_remote" % (self.name)
print(self.result_txt)
return res
self.start_environment()
if self.verbose:
print("\n--- START TEST - %s" % self.name)
self.result_txt = "SUCCESS - '%s'" % (self.name)
self.result_exitcode = CrmExit.OK
for cmd in self.cmds:
try:
self.run_cmd(cmd)
except ExitCodeError as e:
print(cmd['cmd_output'])
print("Step %d FAILED - command returned %s, expected %d" % (i, e, cmd['expected_exitcode']))
self.set_error(i, cmd);
break
except OutputNotFoundError as e:
print("Step %d FAILED - '%s' was not found in command output: %s" % (i, cmd['stdout_match'], e))
self.set_error(i, cmd);
break
except OutputFoundError as e:
print("Step %d FAILED - '%s' was found in command output: %s" % (i, cmd['stdout_negative_match'], e))
self.set_error(i, cmd);
break
if self.verbose:
print(cmd['cmd_output'].strip())
print("Step %d SUCCESS" % (i))
i = i + 1
self.clean_environment()
print(self.result_txt)
if self.verbose:
print("--- END TEST - %s\n" % self.name)
self.executed = 1
return res
class Tests(object):
""" Collection of all pacemaker-execd regression tests """
- def __init__(self, verbose=0, tls=0, timeout=2, force_wait=0):
+ def __init__(self, verbose=0, tls=0, timeout=2, force_wait=0,
+ logdir="/tmp"):
+
self.tests = []
self.verbose = verbose
self.tls = tls
self.timeout = timeout
self.force_wait = force_wait
+ self.logdir = logdir
self.rsc_classes = output_from_command("crm_resource --list-standards")
self.rsc_classes = self.rsc_classes[:-1] # Strip trailing empty line
self.installed_files = []
self.action_timeout = " -t 9000 "
if self.tls:
self.rsc_classes.remove("stonith")
if "systemd" in self.rsc_classes:
try:
# This code doesn't need this import, but pacemaker-cts-dummyd
# does, so ensure the dependency is available rather than cause
# all systemd tests to fail.
import systemd.daemon
except ImportError:
print("Python systemd bindings not found.")
print("The tests for systemd class are not going to be run.")
self.rsc_classes.remove("systemd")
print("Testing resource classes", repr(self.rsc_classes))
self.common_cmds = {
"ocf_reg_line" : "-c register_rsc -r ocf_test_rsc "+self.action_timeout+" -C ocf -P pacemaker -T Dummy",
"ocf_reg_event" : "-l \"NEW_EVENT event_type:register rsc_id:ocf_test_rsc action:none rc:ok op_status:complete\"",
"ocf_unreg_line" : "-c unregister_rsc -r \"ocf_test_rsc\" "+self.action_timeout,
"ocf_unreg_event" : "-l \"NEW_EVENT event_type:unregister rsc_id:ocf_test_rsc action:none rc:ok op_status:complete\"",
"ocf_start_line" : "-c exec -r \"ocf_test_rsc\" -a \"start\" "+self.action_timeout,
"ocf_start_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:ocf_test_rsc action:start rc:ok op_status:complete\" ",
"ocf_stop_line" : "-c exec -r \"ocf_test_rsc\" -a \"stop\" "+self.action_timeout,
"ocf_stop_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:ocf_test_rsc action:stop rc:ok op_status:complete\" ",
"ocf_monitor_line" : '-c exec -r ocf_test_rsc -a monitor -i 2s ' + self.action_timeout,
"ocf_monitor_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:ocf_test_rsc action:monitor rc:ok op_status:complete\" "+self.action_timeout,
"ocf_cancel_line" : '-c cancel -r ocf_test_rsc -a monitor -i 2s ' + self.action_timeout,
"ocf_cancel_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:ocf_test_rsc action:monitor rc:ok op_status:Cancelled\" ",
"systemd_reg_line" : "-c register_rsc -r systemd_test_rsc " +
self.action_timeout +
" -C systemd -T pacemaker-cts-dummyd@3",
"systemd_reg_event" : "-l \"NEW_EVENT event_type:register rsc_id:systemd_test_rsc action:none rc:ok op_status:complete\"",
"systemd_unreg_line" : "-c unregister_rsc -r \"systemd_test_rsc\" "+self.action_timeout,
"systemd_unreg_event" : "-l \"NEW_EVENT event_type:unregister rsc_id:systemd_test_rsc action:none rc:ok op_status:complete\"",
"systemd_start_line" : "-c exec -r \"systemd_test_rsc\" -a \"start\" "+self.action_timeout,
"systemd_start_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:systemd_test_rsc action:start rc:ok op_status:complete\" ",
"systemd_stop_line" : "-c exec -r \"systemd_test_rsc\" -a \"stop\" "+self.action_timeout,
"systemd_stop_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:systemd_test_rsc action:stop rc:ok op_status:complete\" ",
"systemd_monitor_line" : '-c exec -r systemd_test_rsc -a monitor -i 2s ' + self.action_timeout,
"systemd_monitor_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:systemd_test_rsc action:monitor rc:ok op_status:complete\" -t 15000 ",
"systemd_cancel_line" : '-c cancel -r systemd_test_rsc -a monitor -i 2s ' + self.action_timeout,
"systemd_cancel_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:systemd_test_rsc action:monitor rc:ok op_status:Cancelled\" ",
"upstart_reg_line" : "-c register_rsc -r upstart_test_rsc "+self.action_timeout+" -C upstart -T pacemaker-cts-dummyd",
"upstart_reg_event" : "-l \"NEW_EVENT event_type:register rsc_id:upstart_test_rsc action:none rc:ok op_status:complete\"",
"upstart_unreg_line" : "-c unregister_rsc -r \"upstart_test_rsc\" "+self.action_timeout,
"upstart_unreg_event" : "-l \"NEW_EVENT event_type:unregister rsc_id:upstart_test_rsc action:none rc:ok op_status:complete\"",
"upstart_start_line" : "-c exec -r \"upstart_test_rsc\" -a \"start\" "+self.action_timeout,
"upstart_start_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:upstart_test_rsc action:start rc:ok op_status:complete\" ",
"upstart_stop_line" : "-c exec -r \"upstart_test_rsc\" -a \"stop\" "+self.action_timeout,
"upstart_stop_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:upstart_test_rsc action:stop rc:ok op_status:complete\" ",
"upstart_monitor_line" : '-c exec -r upstart_test_rsc -a monitor -i 2s ' + self.action_timeout,
"upstart_monitor_event" : '-l "NEW_EVENT event_type:exec_complete rsc_id:upstart_test_rsc action:monitor rc:ok op_status:complete" -t 15000',
"upstart_cancel_line" : '-c cancel -r upstart_test_rsc -a monitor -i 2s ' + self.action_timeout,
"upstart_cancel_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:upstart_test_rsc action:monitor rc:ok op_status:Cancelled\" ",
"service_reg_line" : "-c register_rsc -r service_test_rsc "+self.action_timeout+" -C service -T LSBDummy",
"service_reg_event" : "-l \"NEW_EVENT event_type:register rsc_id:service_test_rsc action:none rc:ok op_status:complete\"",
"service_unreg_line" : "-c unregister_rsc -r \"service_test_rsc\" "+self.action_timeout,
"service_unreg_event" : "-l \"NEW_EVENT event_type:unregister rsc_id:service_test_rsc action:none rc:ok op_status:complete\"",
"service_start_line" : "-c exec -r \"service_test_rsc\" -a \"start\" "+self.action_timeout,
"service_start_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:service_test_rsc action:start rc:ok op_status:complete\" ",
"service_stop_line" : "-c exec -r \"service_test_rsc\" -a \"stop\" "+self.action_timeout,
"service_stop_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:service_test_rsc action:stop rc:ok op_status:complete\" ",
"service_monitor_line" : '-c exec -r service_test_rsc -a monitor -i 2s ' + self.action_timeout,
"service_monitor_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:service_test_rsc action:monitor rc:ok op_status:complete\" "+self.action_timeout,
"service_cancel_line" : '-c cancel -r service_test_rsc -a monitor -i 2s ' + self.action_timeout,
"service_cancel_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:service_test_rsc action:monitor rc:ok op_status:Cancelled\" ",
"lsb_reg_line" : "-c register_rsc -r lsb_test_rsc "+self.action_timeout+" -C lsb -T LSBDummy",
"lsb_reg_event" : "-l \"NEW_EVENT event_type:register rsc_id:lsb_test_rsc action:none rc:ok op_status:complete\" ",
"lsb_unreg_line" : "-c unregister_rsc -r \"lsb_test_rsc\" "+self.action_timeout,
"lsb_unreg_event" : "-l \"NEW_EVENT event_type:unregister rsc_id:lsb_test_rsc action:none rc:ok op_status:complete\"",
"lsb_start_line" : "-c exec -r \"lsb_test_rsc\" -a \"start\" "+self.action_timeout,
"lsb_start_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:lsb_test_rsc action:start rc:ok op_status:complete\" ",
"lsb_stop_line" : "-c exec -r \"lsb_test_rsc\" -a \"stop\" "+self.action_timeout,
"lsb_stop_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:lsb_test_rsc action:stop rc:ok op_status:complete\" ",
"lsb_monitor_line" : '-c exec -r lsb_test_rsc -a status -i 2s ' + self.action_timeout,
"lsb_monitor_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:lsb_test_rsc action:status rc:ok op_status:complete\" "+self.action_timeout,
"lsb_cancel_line" : '-c cancel -r lsb_test_rsc -a status -i 2s ' + self.action_timeout,
"lsb_cancel_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:lsb_test_rsc action:status rc:ok op_status:Cancelled\" ",
"stonith_reg_line" : "-c register_rsc -r stonith_test_rsc " + self.action_timeout +
" -C stonith -P pacemaker -T fence_dummy",
"stonith_reg_event" : "-l \"NEW_EVENT event_type:register rsc_id:stonith_test_rsc action:none rc:ok op_status:complete\" ",
"stonith_unreg_line" : "-c unregister_rsc -r \"stonith_test_rsc\" "+self.action_timeout,
"stonith_unreg_event" : "-l \"NEW_EVENT event_type:unregister rsc_id:stonith_test_rsc action:none rc:ok op_status:complete\"",
"stonith_start_line" : '-c exec -r stonith_test_rsc -a start ' + self.action_timeout,
"stonith_start_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:stonith_test_rsc action:start rc:ok op_status:complete\" ",
"stonith_stop_line" : "-c exec -r \"stonith_test_rsc\" -a \"stop\" "+self.action_timeout,
"stonith_stop_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:stonith_test_rsc action:stop rc:ok op_status:complete\" ",
"stonith_monitor_line" : '-c exec -r stonith_test_rsc -a monitor -i 2s ' + self.action_timeout,
"stonith_monitor_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:stonith_test_rsc action:monitor rc:ok op_status:complete\" "+self.action_timeout,
"stonith_cancel_line" : '-c cancel -r stonith_test_rsc -a monitor -i 2s ' + self.action_timeout,
"stonith_cancel_event" : "-l \"NEW_EVENT event_type:exec_complete rsc_id:stonith_test_rsc action:monitor rc:ok op_status:Cancelled\" ",
}
def new_test(self, name, description):
""" Create a named test """
- test = Test(name, description, self.verbose, self.tls, self.timeout, self.force_wait)
+ test = Test(name, description, self.verbose, self.tls, self.timeout,
+ self.force_wait, self.logdir)
self.tests.append(test)
return test
def setup_test_environment(self):
""" Prepare the host before executing any tests """
if REMOTE_ENABLED:
os.system("service pacemaker_remote stop")
self.cleanup_test_environment()
if self.tls and not os.path.isfile("/etc/pacemaker/authkey"):
print("Installing /etc/pacemaker/authkey ...")
os.system("mkdir -p /etc/pacemaker")
os.system("dd if=/dev/urandom of=/etc/pacemaker/authkey bs=4096 count=1")
self.installed_files.append("/etc/pacemaker/authkey")
# If we're in build directory, install agents if not already installed
if os.path.exists("%s/cts/cts-exec.in" % BUILD_DIR):
if not os.path.exists("@OCF_RA_INSTALL_DIR@/pacemaker"):
# @TODO remember which components were created and remove them
os.makedirs("@OCF_RA_INSTALL_DIR@/pacemaker", 0o755)
for agent in ["Dummy", "Stateful", "ping"]:
agent_source = "%s/extra/resources/%s" % (BUILD_DIR, agent)
agent_dest = "@OCF_RA_INSTALL_DIR@/pacemaker/%s" % (agent)
if not os.path.exists(agent_dest):
print("Installing %s ..." % (agent_dest))
shutil.copyfile(agent_source, agent_dest)
os.chmod(agent_dest, EXECMODE)
self.installed_files.append(agent_dest)
subprocess.call(["cts-support", "install"])
def cleanup_test_environment(self):
""" Clean up the host after executing desired tests """
for installed_file in self.installed_files:
print("Removing %s ..." % (installed_file))
os.remove(installed_file)
subprocess.call(["cts-support", "uninstall"])
def build_generic_tests(self):
""" Register tests that apply to all resource classes """
common_cmds = self.common_cmds
### register/unregister tests ###
for rsc in self.rsc_classes:
test = self.new_test("generic_registration_%s" % (rsc),
"Simple resource registration test for %s standard" % (rsc))
test.add_cmd(common_cmds["%s_reg_line" % (rsc)] + " " + common_cmds["%s_reg_event" % (rsc)])
test.add_cmd(common_cmds["%s_unreg_line" % (rsc)] + " " + common_cmds["%s_unreg_event" % (rsc)])
### start/stop tests ###
for rsc in self.rsc_classes:
test = self.new_test("generic_start_stop_%s" % (rsc), "Simple start and stop test for %s standard" % (rsc))
test.add_cmd(common_cmds["%s_reg_line" % (rsc)] + " " + common_cmds["%s_reg_event" % (rsc)])
test.add_cmd(common_cmds["%s_start_line" % (rsc)] + " " + common_cmds["%s_start_event" % (rsc)])
test.add_cmd(common_cmds["%s_stop_line" % (rsc)] + " " + common_cmds["%s_stop_event" % (rsc)])
test.add_cmd(common_cmds["%s_unreg_line" % (rsc)] + " " + common_cmds["%s_unreg_event" % (rsc)])
### monitor cancel test ###
for rsc in self.rsc_classes:
test = self.new_test("generic_monitor_cancel_%s" % (rsc),
"Simple monitor cancel test for %s standard" % (rsc))
test.add_cmd(common_cmds["%s_reg_line" % (rsc)] + " " + common_cmds["%s_reg_event" % (rsc)])
test.add_cmd(common_cmds["%s_start_line" % (rsc)] + " " + common_cmds["%s_start_event" % (rsc)])
test.add_cmd(common_cmds["%s_monitor_line" % (rsc)] + " " + common_cmds["%s_monitor_event" % (rsc)])
### If this fails, that means the monitor may not be getting rescheduled ####
test.add_cmd(common_cmds["%s_monitor_event" % (rsc)])
### If this fails, that means the monitor may not be getting rescheduled ####
test.add_cmd(common_cmds["%s_monitor_event" % (rsc)])
test.add_cmd(common_cmds["%s_cancel_line" % (rsc)] + " " + common_cmds["%s_cancel_event" % (rsc)])
### If this happens the monitor did not actually cancel correctly. ###
test.add_expected_fail_cmd(common_cmds["%s_monitor_event" % (rsc)], CrmExit.TIMEOUT)
### If this happens the monitor did not actually cancel correctly. ###
test.add_expected_fail_cmd(common_cmds["%s_monitor_event" % (rsc)], CrmExit.TIMEOUT)
test.add_cmd(common_cmds["%s_stop_line" % (rsc)] + " " + common_cmds["%s_stop_event" % (rsc)])
test.add_cmd(common_cmds["%s_unreg_line" % (rsc)] + " " + common_cmds["%s_unreg_event" % (rsc)])
### monitor duplicate test ###
for rsc in self.rsc_classes:
test = self.new_test("generic_monitor_duplicate_%s" % (rsc),
"Test creation and canceling of duplicate monitors for %s standard" % (rsc))
test.add_cmd(common_cmds["%s_reg_line" % (rsc)] + " " + common_cmds["%s_reg_event" % (rsc)])
test.add_cmd(common_cmds["%s_start_line" % (rsc)] + " " + common_cmds["%s_start_event" % (rsc)])
test.add_cmd(common_cmds["%s_monitor_line" % (rsc)] + " " + common_cmds["%s_monitor_event" % (rsc)])
### If this fails, that means the monitor may not be getting rescheduled ####
test.add_cmd(common_cmds["%s_monitor_event" % (rsc)])
### If this fails, that means the monitor may not be getting rescheduled ####
test.add_cmd(common_cmds["%s_monitor_event" % (rsc)])
# Add the duplicate monitors
test.add_cmd(common_cmds["%s_monitor_line" % (rsc)] + " " + common_cmds["%s_monitor_event" % (rsc)])
test.add_cmd(common_cmds["%s_monitor_line" % (rsc)] + " " + common_cmds["%s_monitor_event" % (rsc)])
test.add_cmd(common_cmds["%s_monitor_line" % (rsc)] + " " + common_cmds["%s_monitor_event" % (rsc)])
test.add_cmd(common_cmds["%s_monitor_line" % (rsc)] + " " + common_cmds["%s_monitor_event" % (rsc)])
# verify we still get update events
### If this fails, that means the monitor may not be getting rescheduled ####
test.add_cmd(common_cmds["%s_monitor_event" % (rsc)])
# cancel the monitor, if the duplicate merged with the original, we should no longer see monitor updates
test.add_cmd(common_cmds["%s_cancel_line" % (rsc)] + " " + common_cmds["%s_cancel_event" % (rsc)])
### If this happens the monitor did not actually cancel correctly. ###
test.add_expected_fail_cmd(common_cmds["%s_monitor_event" % (rsc)], CrmExit.TIMEOUT)
### If this happens the monitor did not actually cancel correctly. ###
test.add_expected_fail_cmd(common_cmds["%s_monitor_event" % (rsc)], CrmExit.TIMEOUT)
test.add_cmd(common_cmds["%s_stop_line" % (rsc)] + " " + common_cmds["%s_stop_event" % (rsc)])
test.add_cmd(common_cmds["%s_unreg_line" % (rsc)] + " " + common_cmds["%s_unreg_event" % (rsc)])
### stop implies cancel test ###
for rsc in self.rsc_classes:
test = self.new_test("generic_stop_implies_cancel_%s" % (rsc),
"Verify stopping a resource implies cancel of recurring ops for %s standard" % (rsc))
test.add_cmd(common_cmds["%s_reg_line" % (rsc)] + " " + common_cmds["%s_reg_event" % (rsc)])
test.add_cmd(common_cmds["%s_start_line" % (rsc)] + " " + common_cmds["%s_start_event" % (rsc)])
test.add_cmd(common_cmds["%s_monitor_line" % (rsc)] + " " + common_cmds["%s_monitor_event" % (rsc)])
### If this fails, that means the monitor may not be getting rescheduled ####
test.add_cmd(common_cmds["%s_monitor_event" % (rsc)])
### If this fails, that means the monitor may not be getting rescheduled ####
test.add_cmd(common_cmds["%s_monitor_event" % (rsc)])
test.add_cmd(common_cmds["%s_stop_line" % (rsc)] + " " + common_cmds["%s_stop_event" % (rsc)])
### If this happens the monitor did not actually cancel correctly. ###
test.add_expected_fail_cmd(common_cmds["%s_monitor_event" % (rsc)], CrmExit.TIMEOUT)
### If this happens the monitor did not actually cancel correctly. ###
test.add_expected_fail_cmd(common_cmds["%s_monitor_event" % (rsc)], CrmExit.TIMEOUT)
test.add_cmd(common_cmds["%s_unreg_line" % (rsc)] + " " + common_cmds["%s_unreg_event" % (rsc)])
def build_multi_rsc_tests(self):
""" Register complex tests that involve managing multiple resouces of different types """
common_cmds = self.common_cmds
# do not use service and systemd at the same time, it is the same resource.
### register start monitor stop unregister resources of each type at the same time. ###
test = self.new_test("multi_rsc_start_stop_all",
"Start, monitor, and stop resources of multiple types and classes")
for rsc in self.rsc_classes:
test.add_cmd(common_cmds["%s_reg_line" % (rsc)] + " " + common_cmds["%s_reg_event" % (rsc)])
for rsc in self.rsc_classes:
test.add_cmd(common_cmds["%s_start_line" % (rsc)] + " " + common_cmds["%s_start_event" % (rsc)])
for rsc in self.rsc_classes:
test.add_cmd(common_cmds["%s_monitor_line" % (rsc)] + " " + common_cmds["%s_monitor_event" % (rsc)])
for rsc in self.rsc_classes:
### If this fails, that means the monitor is not being rescheduled ####
test.add_cmd(common_cmds["%s_monitor_event" % (rsc)])
for rsc in self.rsc_classes:
test.add_cmd(common_cmds["%s_cancel_line" % (rsc)] + " " + common_cmds["%s_cancel_event" % (rsc)])
for rsc in self.rsc_classes:
test.add_cmd(common_cmds["%s_stop_line" % (rsc)] + " " + common_cmds["%s_stop_event" % (rsc)])
for rsc in self.rsc_classes:
test.add_cmd(common_cmds["%s_unreg_line" % (rsc)] + " " + common_cmds["%s_unreg_event" % (rsc)])
def build_negative_tests(self):
""" Register tests related to how pacemaker-execd handles failures """
### ocf start timeout test ###
test = self.new_test("ocf_start_timeout", "Force start timeout to occur, verify start failure.")
test.add_cmd("-c register_rsc -r \"test_rsc\" -C \"ocf\" -P \"pacemaker\" -T \"Dummy\" "
+ self.action_timeout +
"-l \"NEW_EVENT event_type:register rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
# -t must be less than self.action_timeout
test.add_cmd("-c exec -r \"test_rsc\" -a \"start\" -k \"op_sleep\" -v \"5\" -t 1000 -w")
test.add_cmd('-l "NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:error op_status:Timed Out" '
+ self.action_timeout)
test.add_cmd("-c exec -r test_rsc -a stop " + self.action_timeout +
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:stop rc:ok op_status:complete\" ")
test.add_cmd("-c unregister_rsc -r test_rsc " + self.action_timeout +
"-l \"NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
### stonith start timeout test ###
test = self.new_test("stonith_start_timeout", "Force start timeout to occur, verify start failure.")
test.add_cmd('-c register_rsc -r test_rsc ' +
'-C stonith -P pacemaker -T fence_dummy ' +
self.action_timeout +
'-l "NEW_EVENT event_type:register rsc_id:test_rsc action:none rc:ok op_status:complete"')
test.add_cmd('-c exec -r test_rsc -a start -k monitor_delay -v 30 ' +
'-t 1000 -w') # -t must be less than self.action_timeout
test.add_cmd('-l "NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:OCF_TIMEOUT op_status:Timed Out" '
+ self.action_timeout)
test.add_cmd("-c exec -r test_rsc -a stop " + self.action_timeout +
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:stop rc:ok op_status:complete\" ")
test.add_cmd("-c unregister_rsc -r test_rsc " + self.action_timeout +
"-l \"NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
### stonith component fail ###
common_cmds = self.common_cmds
test = self.new_test("stonith_component_fail", "Kill stonith component after pacemaker-execd connects")
test.add_cmd(common_cmds["stonith_reg_line"] + " " + common_cmds["stonith_reg_event"])
test.add_cmd(common_cmds["stonith_start_line"] + " " + common_cmds["stonith_start_event"])
test.add_cmd('-c exec -r stonith_test_rsc -a monitor -i 600s '
'-l "NEW_EVENT event_type:exec_complete rsc_id:stonith_test_rsc action:monitor rc:ok op_status:complete" '
+ self.action_timeout)
test.add_cmd_and_kill("killall -9 -q pacemaker-fenced lt-pacemaker-fenced",
'-l "NEW_EVENT event_type:exec_complete rsc_id:stonith_test_rsc action:monitor rc:error op_status:error" -t 15000')
test.add_cmd(common_cmds["stonith_unreg_line"] + " " + common_cmds["stonith_unreg_event"])
### monitor fail for ocf resources ###
test = self.new_test("monitor_fail_ocf", "Force ocf monitor to fail, verify failure is reported.")
test.add_cmd("-c register_rsc -r \"test_rsc\" -C \"ocf\" -P \"pacemaker\" -T \"Dummy\" "
+ self.action_timeout +
"-l \"NEW_EVENT event_type:register rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
test.add_cmd("-c exec -r \"test_rsc\" -a \"start\" " + self.action_timeout +
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:ok op_status:complete\" ")
test.add_cmd("-c exec -r \"test_rsc\" -a \"start\" " + self.action_timeout +
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:ok op_status:complete\" ")
test.add_cmd('-c exec -r test_rsc -a monitor -i 1s '
+ self.action_timeout +
'-l "NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete"')
test.add_cmd('-l "NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete"'
+ self.action_timeout)
test.add_cmd('-l "NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete"'
+ self.action_timeout)
test.add_cmd_and_kill("rm -f @localstatedir@/run/Dummy-test_rsc.state",
'-l "NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:not running op_status:complete" ' + self.action_timeout)
test.add_cmd('-c cancel -r test_rsc -a monitor -i 1s ' + self.action_timeout +
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:not running op_status:Cancelled\" ")
test.add_expected_fail_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:not running op_status:complete\" "
+ self.action_timeout, CrmExit.TIMEOUT)
test.add_expected_fail_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete\" "
+ self.action_timeout, CrmExit.TIMEOUT)
test.add_cmd("-c unregister_rsc -r \"test_rsc\" "
+ self.action_timeout +
"-l \"NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
### verify notify changes only for monitor operation. ###
test = self.new_test("monitor_changes_only", "Verify when flag is set, only monitor changes are notified.")
test.add_cmd("-c register_rsc -r \"test_rsc\" -C \"ocf\" -P \"pacemaker\" -T \"Dummy\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:register rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
test.add_cmd("-c exec -r \"test_rsc\" -a \"start\" "+self.action_timeout+" -o "
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:ok op_status:complete\" ")
test.add_cmd('-c exec -r test_rsc -a monitor -i 1s '
+ self.action_timeout +
' -o -l "NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete" ')
test.add_expected_fail_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete\" "+self.action_timeout, CrmExit.TIMEOUT)
test.add_cmd_and_kill('rm -f @localstatedir@/run/Dummy-test_rsc.state', '-l "NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:not running op_status:complete"' + self.action_timeout)
test.add_cmd('-c cancel -r test_rsc -a monitor -i 1s'
+ self.action_timeout +
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:not running op_status:Cancelled\" ")
test.add_expected_fail_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:not running op_status:complete\" "+self.action_timeout, CrmExit.TIMEOUT)
test.add_expected_fail_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete\" "+self.action_timeout, CrmExit.TIMEOUT)
test.add_cmd('-c unregister_rsc -r "test_rsc" ' + self.action_timeout +
'-l "NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete"')
### monitor fail for systemd resource ###
if "systemd" in self.rsc_classes:
test = self.new_test("monitor_fail_systemd", "Force systemd monitor to fail, verify failure is reported..")
test.add_cmd("-c register_rsc -r \"test_rsc\" -C systemd -T pacemaker-cts-dummyd@3 " +
self.action_timeout +
"-l \"NEW_EVENT event_type:register rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
test.add_cmd("-c exec -r \"test_rsc\" -a \"start\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:ok op_status:complete\" ")
test.add_cmd("-c exec -r \"test_rsc\" -a \"start\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:ok op_status:complete\" ")
test.add_cmd('-c exec -r test_rsc -a monitor -i 1s '
+ self.action_timeout +
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete\" ")
test.add_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete\" "+self.action_timeout)
test.add_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete\" "+self.action_timeout)
test.add_cmd_and_kill("pkill -9 -f pacemaker-cts-dummyd",
'-l "NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:not running op_status:complete"' + self.action_timeout)
test.add_cmd('-c cancel -r test_rsc -a monitor -i 1s' + self.action_timeout +
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:not running op_status:Cancelled\" ")
test.add_expected_fail_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:not running op_status:complete\" "+self.action_timeout, CrmExit.TIMEOUT)
test.add_expected_fail_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete\" "+self.action_timeout, CrmExit.TIMEOUT)
test.add_cmd("-c unregister_rsc -r \"test_rsc\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
### monitor fail for upstart resource ###
if "upstart" in self.rsc_classes:
test = self.new_test("monitor_fail_upstart", "Force upstart monitor to fail, verify failure is reported..")
test.add_cmd("-c register_rsc -r \"test_rsc\" -C upstart -T pacemaker-cts-dummyd "+self.action_timeout+
"-l \"NEW_EVENT event_type:register rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
test.add_cmd("-c exec -r \"test_rsc\" -a \"start\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:ok op_status:complete\" ")
test.add_cmd("-c exec -r \"test_rsc\" -a \"start\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:ok op_status:complete\" ")
test.add_cmd('-c exec -r test_rsc -a monitor -i 1s ' + self.action_timeout +
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete\" ")
test.add_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete\" "+self.action_timeout)
test.add_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete\" "+self.action_timeout)
test.add_cmd_and_kill('killall -9 -q dd', '-l "NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:not running op_status:complete"' + self.action_timeout)
test.add_cmd('-c cancel -r test_rsc -a monitor -i 1s'
+ self.action_timeout +
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:not running op_status:Cancelled\" ")
test.add_expected_fail_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:not running op_status:complete\" "+self.action_timeout, CrmExit.TIMEOUT)
test.add_expected_fail_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete\" "+self.action_timeout, CrmExit.TIMEOUT)
test.add_cmd("-c unregister_rsc -r \"test_rsc\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
### Cancel non-existent operation on a resource ###
test = self.new_test("cancel_non_existent_op", "Attempt to cancel the wrong monitor operation, verify expected failure")
test.add_cmd("-c register_rsc -r \"test_rsc\" -C \"ocf\" -P \"pacemaker\" -T \"Dummy\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:register rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
test.add_cmd("-c exec -r \"test_rsc\" -a \"start\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:ok op_status:complete\" ")
test.add_cmd("-c exec -r \"test_rsc\" -a \"start\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:ok op_status:complete\" ")
test.add_cmd('-c exec -r test_rsc -a monitor -i 1s '
+ self.action_timeout +
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete\" ")
test.add_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete\" "+self.action_timeout)
### interval is wrong, should fail
test.add_expected_fail_cmd('-c cancel -r test_rsc -a monitor -i 2s' + self.action_timeout +
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:not running op_status:Cancelled\" ")
### action name is wrong, should fail
test.add_expected_fail_cmd('-c cancel -r test_rsc -a stop -i 1s' + self.action_timeout +
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:not running op_status:Cancelled\" ")
test.add_cmd("-c unregister_rsc -r \"test_rsc\" " + self.action_timeout +
"-l \"NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
### Attempt to invoke non-existent rsc id ###
test = self.new_test("invoke_non_existent_rsc", "Attempt to perform operations on a non-existent rsc id.")
test.add_expected_fail_cmd("-c exec -r \"test_rsc\" -a \"start\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:error op_status:complete\" ")
test.add_expected_fail_cmd("-c exec -r test_rsc -a stop "+self.action_timeout+
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:stop rc:ok op_status:complete\" ")
test.add_expected_fail_cmd('-c exec -r test_rsc -a monitor -i 6s '
+ self.action_timeout +
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete\" ")
test.add_expected_fail_cmd("-c cancel -r test_rsc -a start "+self.action_timeout+
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:ok op_status:Cancelled\" ")
test.add_cmd("-c unregister_rsc -r \"test_rsc\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
### Register and start a resource that doesn't exist, systemd ###
if "systemd" in self.rsc_classes:
test = self.new_test("start_uninstalled_systemd", "Register uninstalled systemd agent, try to start, verify expected failure")
test.add_cmd("-c register_rsc -r \"test_rsc\" -C systemd -T this_is_fake1234 "+self.action_timeout+
"-l \"NEW_EVENT event_type:register rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
test.add_cmd("-c exec -r \"test_rsc\" -a \"start\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:not installed op_status:Not installed\" ")
test.add_cmd("-c unregister_rsc -r \"test_rsc\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
if "upstart" in self.rsc_classes:
test = self.new_test("start_uninstalled_upstart", "Register uninstalled upstart agent, try to start, verify expected failure")
test.add_cmd("-c register_rsc -r \"test_rsc\" -C upstart -T this_is_fake1234 "+self.action_timeout+
"-l \"NEW_EVENT event_type:register rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
test.add_cmd("-c exec -r \"test_rsc\" -a \"start\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:not installed op_status:Not installed\" ")
test.add_cmd("-c unregister_rsc -r \"test_rsc\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
### Register and start a resource that doesn't exist, ocf ###
test = self.new_test("start_uninstalled_ocf", "Register uninstalled ocf agent, try to start, verify expected failure.")
test.add_cmd("-c register_rsc -r \"test_rsc\" -C ocf -P pacemaker -T this_is_fake1234 "+self.action_timeout+
"-l \"NEW_EVENT event_type:register rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
test.add_cmd("-c exec -r \"test_rsc\" -a \"start\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:not installed op_status:Not installed\" ")
test.add_cmd("-c unregister_rsc -r \"test_rsc\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
### Register ocf with non-existent provider ###
test = self.new_test("start_ocf_bad_provider", "Register ocf agent with a non-existent provider, verify expected failure.")
test.add_cmd("-c register_rsc -r \"test_rsc\" -C ocf -P pancakes -T Dummy "+self.action_timeout+
"-l \"NEW_EVENT event_type:register rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
test.add_cmd("-c exec -r \"test_rsc\" -a \"start\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:not installed op_status:Not installed\" ")
test.add_cmd("-c unregister_rsc -r \"test_rsc\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
### Register ocf with empty provider field ###
test = self.new_test("start_ocf_no_provider", "Register ocf agent with a no provider, verify expected failure.")
test.add_expected_fail_cmd("-c register_rsc -r \"test_rsc\" -C ocf -T Dummy "+self.action_timeout+
"-l \"NEW_EVENT event_type:register rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
test.add_expected_fail_cmd("-c exec -r \"test_rsc\" -a \"start\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:ok op_status:Error\" ")
test.add_cmd("-c unregister_rsc -r \"test_rsc\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
def build_stress_tests(self):
""" Register stress tests """
timeout = "-t 20000"
iterations = 25
test = self.new_test("ocf_stress", "Verify OCF agent handling works under load")
for i in range(iterations):
test.add_cmd("-c register_rsc -r rsc_%s %s -C ocf -P heartbeat -T Dummy -l \"NEW_EVENT event_type:register rsc_id:rsc_%s action:none rc:ok op_status:complete\"" % (i, timeout, i))
test.add_cmd("-c exec -r rsc_%s -a start %s -l \"NEW_EVENT event_type:exec_complete rsc_id:rsc_%s action:start rc:ok op_status:complete\"" % (i, timeout, i))
test.add_cmd('-c exec -r rsc_%s -a monitor %s -i 1s '
'-l "NEW_EVENT event_type:exec_complete rsc_id:rsc_%s action:monitor rc:ok op_status:complete"' % (i, timeout, i))
for i in range(iterations):
test.add_cmd("-c exec -r rsc_%s -a stop %s -l \"NEW_EVENT event_type:exec_complete rsc_id:rsc_%s action:stop rc:ok op_status:complete\"" % (i, timeout, i))
test.add_cmd("-c unregister_rsc -r rsc_%s %s -l \"NEW_EVENT event_type:unregister rsc_id:rsc_%s action:none rc:ok op_status:complete\"" % (i, timeout, i))
if "systemd" in self.rsc_classes:
test = self.new_test("systemd_stress", "Verify systemd dbus connection works under load")
for i in range(iterations):
test.add_cmd("-c register_rsc -r rsc_%s %s -C systemd -T pacemaker-cts-dummyd@3 -l \"NEW_EVENT event_type:register rsc_id:rsc_%s action:none rc:ok op_status:complete\"" % (i, timeout, i))
test.add_cmd("-c exec -r rsc_%s -a start %s -l \"NEW_EVENT event_type:exec_complete rsc_id:rsc_%s action:start rc:ok op_status:complete\"" % (i, timeout, i))
test.add_cmd('-c exec -r rsc_%s -a monitor %s -i 1s '
'-l "NEW_EVENT event_type:exec_complete rsc_id:rsc_%s action:monitor rc:ok op_status:complete"' % (i, timeout, i))
for i in range(iterations):
test.add_cmd("-c exec -r rsc_%s -a stop %s -l \"NEW_EVENT event_type:exec_complete rsc_id:rsc_%s action:stop rc:ok op_status:complete\"" % (i, timeout, i))
test.add_cmd("-c unregister_rsc -r rsc_%s %s -l \"NEW_EVENT event_type:unregister rsc_id:rsc_%s action:none rc:ok op_status:complete\"" % (i, timeout, i))
iterations = 9
timeout = "-t 30000"
### Verify recurring op in-flight collision is handled in series properly
test = self.new_test("rsc_inflight_collision", "Verify recurring ops do not collide with other operations for the same rsc.")
test.add_cmd("-c register_rsc -r test_rsc -P pacemaker -C ocf -T Dummy "
"-l \"NEW_EVENT event_type:register rsc_id:test_rsc action:none rc:ok op_status:complete\" "+self.action_timeout)
test.add_cmd("-c exec -r test_rsc -a start %s -k op_sleep -v 1 -l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:ok op_status:complete\"" % (timeout))
for i in range(iterations):
test.add_cmd('-c exec -r test_rsc -a monitor %s -i 100%dms '
'-k op_sleep -v 2 '
'-l "NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete"' % (timeout, i))
test.add_cmd("-c exec -r test_rsc -a stop %s -l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:stop rc:ok op_status:complete\"" % (timeout))
test.add_cmd("-c unregister_rsc -r test_rsc %s -l \"NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete\"" % (timeout))
def build_custom_tests(self):
""" Register tests that target specific cases """
### verify resource temporary folder is created and used by OCF agents. ###
test = self.new_test("rsc_tmp_dir", "Verify creation and use of rsc temporary state directory")
test.add_sys_cmd("ls", "-al @CRM_RSCTMP_DIR@")
test.add_cmd("-c register_rsc -r test_rsc -P heartbeat -C ocf -T Dummy "
"-l \"NEW_EVENT event_type:register rsc_id:test_rsc action:none rc:ok op_status:complete\" "+self.action_timeout)
test.add_cmd("-c exec -r test_rsc -a start -t 4000")
test.add_sys_cmd("ls", "-al @CRM_RSCTMP_DIR@")
test.add_sys_cmd("ls", "@CRM_RSCTMP_DIR@/Dummy-test_rsc.state")
test.add_cmd("-c exec -r test_rsc -a stop -t 4000")
test.add_cmd("-c unregister_rsc -r test_rsc "+self.action_timeout+
"-l \"NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
### start delay then stop test ###
test = self.new_test("start_delay", "Verify start delay works as expected.")
test.add_cmd("-c register_rsc -r test_rsc -P pacemaker -C ocf -T Dummy "
"-l \"NEW_EVENT event_type:register rsc_id:test_rsc action:none rc:ok op_status:complete\" "+self.action_timeout)
test.add_cmd("-c exec -r test_rsc -s 6000 -a start -w -t 6000")
test.add_expected_fail_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:ok op_status:complete\" -t 2000", CrmExit.TIMEOUT)
test.add_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:ok op_status:complete\" -t 6000")
test.add_cmd("-c exec -r test_rsc -a stop " + self.action_timeout +
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:stop rc:ok op_status:complete\" ")
test.add_cmd("-c unregister_rsc -r test_rsc " + self.action_timeout +
"-l \"NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
### start delay, but cancel before it gets a chance to start. ###
test = self.new_test("start_delay_cancel", "Using start_delay, start a rsc, but cancel the start op before execution.")
test.add_cmd("-c register_rsc -r test_rsc -P pacemaker -C ocf -T Dummy "
"-l \"NEW_EVENT event_type:register rsc_id:test_rsc action:none rc:ok op_status:complete\" "+self.action_timeout)
test.add_cmd("-c exec -r test_rsc -s 5000 -a start -w -t 4000")
test.add_cmd("-c cancel -r test_rsc -a start " + self.action_timeout +
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:ok op_status:Cancelled\" ")
test.add_expected_fail_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:ok op_status:complete\" -t 5000", CrmExit.TIMEOUT)
test.add_cmd("-c unregister_rsc -r test_rsc " + self.action_timeout +
"-l \"NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
### Register a bunch of resources, verify we can get info on them ###
test = self.new_test("verify_get_rsc_info", "Register multiple resources, verify retrieval of rsc info.")
if "systemd" in self.rsc_classes:
test.add_cmd("-c register_rsc -r rsc1 -C systemd -T pacemaker-cts-dummyd@3 "+self.action_timeout)
test.add_cmd("-c get_rsc_info -r rsc1 ")
test.add_cmd("-c unregister_rsc -r rsc1 "+self.action_timeout)
test.add_expected_fail_cmd("-c get_rsc_info -r rsc1 ")
if "upstart" in self.rsc_classes:
test.add_cmd("-c register_rsc -r rsc1 -C upstart -T pacemaker-cts-dummyd "+self.action_timeout)
test.add_cmd("-c get_rsc_info -r rsc1 ")
test.add_cmd("-c unregister_rsc -r rsc1 "+self.action_timeout)
test.add_expected_fail_cmd("-c get_rsc_info -r rsc1 ")
test.add_cmd("-c register_rsc -r rsc2 -C ocf -T Dummy -P pacemaker "+self.action_timeout)
test.add_cmd("-c get_rsc_info -r rsc2 ")
test.add_cmd("-c unregister_rsc -r rsc2 "+self.action_timeout)
test.add_expected_fail_cmd("-c get_rsc_info -r rsc2 ")
### Register duplicate, verify only one entry exists and can still be removed.
test = self.new_test("duplicate_registration", "Register resource multiple times, verify only one entry exists and can be removed.")
test.add_cmd("-c register_rsc -r rsc2 -C ocf -T Dummy -P pacemaker "+self.action_timeout)
test.add_cmd_check_stdout("-c get_rsc_info -r rsc2 ", "id:rsc2 class:ocf provider:pacemaker type:Dummy")
test.add_cmd("-c register_rsc -r rsc2 -C ocf -T Dummy -P pacemaker "+self.action_timeout)
test.add_cmd_check_stdout("-c get_rsc_info -r rsc2 ", "id:rsc2 class:ocf provider:pacemaker type:Dummy")
test.add_cmd("-c register_rsc -r rsc2 -C ocf -T Stateful -P pacemaker "+self.action_timeout)
test.add_cmd_check_stdout("-c get_rsc_info -r rsc2 ", "id:rsc2 class:ocf provider:pacemaker type:Stateful")
test.add_cmd("-c unregister_rsc -r rsc2 "+self.action_timeout)
test.add_expected_fail_cmd("-c get_rsc_info -r rsc2 ")
### verify the option to only send notification to the original client. ###
test = self.new_test("notify_orig_client_only", "Verify option to only send notifications to the client originating the action.")
test.add_cmd("-c register_rsc -r \"test_rsc\" -C \"ocf\" -P \"pacemaker\" -T \"Dummy\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:register rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
test.add_cmd("-c exec -r \"test_rsc\" -a \"start\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:start rc:ok op_status:complete\" ")
test.add_cmd('-c exec -r \"test_rsc\" -a \"monitor\" -i 1s '
+ self.action_timeout + ' -n '
'-l "NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete"')
# this will fail because the monitor notifications should only go to the original caller, which no longer exists.
test.add_expected_fail_cmd("-l \"NEW_EVENT event_type:exec_complete rsc_id:test_rsc action:monitor rc:ok op_status:complete\" "+self.action_timeout, CrmExit.TIMEOUT)
test.add_cmd('-c cancel -r test_rsc -a monitor -i 1s -t 6000 ')
test.add_cmd("-c unregister_rsc -r \"test_rsc\" "+self.action_timeout+
"-l \"NEW_EVENT event_type:unregister rsc_id:test_rsc action:none rc:ok op_status:complete\" ")
### get metadata ###
test = self.new_test("get_ocf_metadata", "Retrieve metadata for a resource")
test.add_cmd_check_stdout("-c metadata -C \"ocf\" -P \"pacemaker\" -T \"Dummy\"",
"resource-agent name=\"Dummy\"")
test.add_cmd("-c metadata -C \"ocf\" -P \"pacemaker\" -T \"Stateful\"")
test.add_expected_fail_cmd("-c metadata -P \"pacemaker\" -T \"Stateful\"")
test.add_expected_fail_cmd("-c metadata -C \"ocf\" -P \"pacemaker\" -T \"fake_agent\"")
### get metadata ###
test = self.new_test("get_lsb_metadata", "Retrieve metadata for a resource")
test.add_cmd_check_stdout("-c metadata -C \"lsb\" -T \"LSBDummy\"",
"resource-agent name='LSBDummy'")
### get stonith metadata ###
test = self.new_test("get_stonith_metadata", "Retrieve stonith metadata for a resource")
test.add_cmd_check_stdout("-c metadata -C \"stonith\" -P \"pacemaker\" -T \"fence_dummy\"",
"resource-agent name=\"fence_dummy\"")
### get metadata ###
if "systemd" in self.rsc_classes:
test = self.new_test("get_systemd_metadata", "Retrieve metadata for a resource")
test.add_cmd_check_stdout("-c metadata -C \"systemd\" -T \"pacemaker-cts-dummyd@\"",
"resource-agent name=\"pacemaker-cts-dummyd@\"")
### get metadata ###
if "upstart" in self.rsc_classes:
test = self.new_test("get_upstart_metadata", "Retrieve metadata for a resource")
test.add_cmd_check_stdout("-c metadata -C \"upstart\" -T \"pacemaker-cts-dummyd\"",
"resource-agent name=\"pacemaker-cts-dummyd\"")
### get ocf providers ###
test = self.new_test("list_ocf_providers",
"Retrieve list of available resource providers, verifies pacemaker is a provider.")
test.add_cmd_check_stdout("-c list_ocf_providers ", "pacemaker")
test.add_cmd_check_stdout("-c list_ocf_providers -T ping", "pacemaker")
### Verify agents only exist in their lists ###
test = self.new_test("verify_agent_lists", "Verify the agent lists contain the right data.")
test.add_cmd_check_stdout("-c list_agents ", "Stateful") ### ocf ###
test.add_cmd_check_stdout("-c list_agents -C ocf", "Stateful")
test.add_cmd_check_stdout("-c list_agents -C lsb", "", "Stateful") ### should not exist
test.add_cmd_check_stdout("-c list_agents -C service", "", "Stateful") ### should not exist
test.add_cmd_check_stdout("-c list_agents ", "LSBDummy") ### init.d ###
test.add_cmd_check_stdout("-c list_agents -C lsb", "LSBDummy")
test.add_cmd_check_stdout("-c list_agents -C service", "LSBDummy")
test.add_cmd_check_stdout("-c list_agents -C ocf", "", "pacemaker-cts-dummyd@") ### should not exist
test.add_cmd_check_stdout("-c list_agents -C ocf", "", "pacemaker-cts-dummyd@") ### should not exist
test.add_cmd_check_stdout("-c list_agents -C lsb", "", "fence_dummy") ### should not exist
test.add_cmd_check_stdout("-c list_agents -C service", "", "fence_dummy") ### should not exist
test.add_cmd_check_stdout("-c list_agents -C ocf", "", "fence_dummy") ### should not exist
if "systemd" in self.rsc_classes:
test.add_cmd_check_stdout("-c list_agents ", "pacemaker-cts-dummyd@") ### systemd ###
test.add_cmd_check_stdout("-c list_agents -C service", "LSBDummy")
test.add_cmd_check_stdout("-c list_agents -C systemd", "", "Stateful") ### should not exist
test.add_cmd_check_stdout("-c list_agents -C systemd", "pacemaker-cts-dummyd@")
test.add_cmd_check_stdout("-c list_agents -C systemd", "", "fence_dummy") ### should not exist
if "upstart" in self.rsc_classes:
test.add_cmd_check_stdout("-c list_agents ", "pacemaker-cts-dummyd") ### upstart ###
test.add_cmd_check_stdout("-c list_agents -C service", "LSBDummy")
test.add_cmd_check_stdout("-c list_agents -C upstart", "", "Stateful") ### should not exist
test.add_cmd_check_stdout("-c list_agents -C upstart", "pacemaker-cts-dummyd")
test.add_cmd_check_stdout("-c list_agents -C upstart", "", "fence_dummy") ### should not exist
if "stonith" in self.rsc_classes:
test.add_cmd_check_stdout("-c list_agents -C stonith", "fence_dummy") ### stonith ###
test.add_cmd_check_stdout("-c list_agents -C stonith", "", "pacemaker-cts-dummyd@") ### should not exist
test.add_cmd_check_stdout("-c list_agents -C stonith", "", "Stateful") ### should not exist
test.add_cmd_check_stdout("-c list_agents ", "fence_dummy")
def print_list(self):
""" List all registered tests """
print("\n==== %d TESTS FOUND ====" % (len(self.tests)))
print("%35s - %s" % ("TEST NAME", "TEST DESCRIPTION"))
print("%35s - %s" % ("--------------------", "--------------------"))
for test in self.tests:
print("%35s - %s" % (test.name, test.description))
print("==== END OF LIST ====\n")
def run_single(self, name):
""" Run a single named test """
for test in self.tests:
if test.name == name:
test.run()
break
def run_tests_matching(self, pattern):
""" Run all tests whose name matches a pattern """
for test in self.tests:
if test.name.count(pattern) != 0:
test.run()
def run_tests(self):
""" Run all tests """
for test in self.tests:
test.run()
def exit(self):
""" Exit (with error status code if any test failed) """
for test in self.tests:
if test.executed == 0:
continue
if test.get_exitcode() != CrmExit.OK:
sys.exit(CrmExit.ERROR)
sys.exit(CrmExit.OK)
def print_results(self):
""" Print summary of results of executed tests """
failures = 0
success = 0
print("\n\n======= FINAL RESULTS ==========")
print("\n--- FAILURE RESULTS:")
for test in self.tests:
if test.executed == 0:
continue
if test.get_exitcode() != CrmExit.OK:
failures = failures + 1
test.print_result(" ")
else:
success = success + 1
if failures == 0:
print(" None")
print("\n--- TOTALS\n Pass:%d\n Fail:%d\n" % (success, failures))
class TestOptions(object):
""" Option handler """
def __init__(self):
self.options = {}
self.options['list-tests'] = 0
self.options['run-all'] = 1
self.options['run-only'] = ""
self.options['run-only-pattern'] = ""
self.options['verbose'] = 0
self.options['timeout'] = 2
self.options['force-wait'] = 0
self.options['invalid-arg'] = ""
self.options['show-usage'] = 0
self.options['pacemaker-remote'] = 0
def build_options(self, argv):
""" Set options based on command-line arguments """
args = argv[1:]
skip = 0
for i in range(0, len(args)):
if skip:
skip = 0
continue
elif args[i] == "-h" or args[i] == "--help":
self.options['show-usage'] = 1
elif args[i] == "-l" or args[i] == "--list-tests":
self.options['list-tests'] = 1
elif args[i] == "-V" or args[i] == "--verbose":
self.options['verbose'] = 1
elif args[i] == "-t" or args[i] == "--timeout":
self.options['timeout'] = float(args[i+1])
elif args[i] == "-w" or args[i] == "--force-wait":
self.options['force-wait'] = 1
elif args[i] == "-R" or args[i] == "--pacemaker-remote":
if REMOTE_ENABLED:
self.options['pacemaker-remote'] = 1
else:
print("ERROR: This build does not support Pacemaker Remote")
sys.exit(CrmExit.USAGE)
elif args[i] == "-r" or args[i] == "--run-only":
self.options['run-only'] = args[i+1]
skip = 1
elif args[i] == "-p" or args[i] == "--run-only-pattern":
self.options['run-only-pattern'] = args[i+1]
skip = 1
def show_usage(self):
""" Show command usage """
print("usage: " + sys.argv[0] + " [options]")
print("If no options are provided, all tests will run")
print("Options:")
print("\t [--help | -h] Show usage")
print("\t [--list-tests | -l] Print out all registered tests.")
print("\t [--run-only | -r 'testname'] Run a specific test")
print("\t [--verbose | -V] Verbose output")
print("\t [--timeout | -t 'floating point number']"
"\n\t\tUp to how many seconds each test case waits for the daemon to be initialized."
"\n\t\tDefaults to 2. The value 0 means no limit.")
print("\t [--force-wait | -w]"
"\n\t\tEach test case waits the default/specified --timeout for the daemon without tracking the log.")
if REMOTE_ENABLED:
print("\t [--pacemaker-remote | -R Test pacemaker-remoted binary instead of pacemaker-execd")
print("\t [--run-only-pattern | -p 'string'] Run only tests containing the string value")
print("\n\tExample: Run only the test 'start_stop'")
print("\t\t " + sys.argv[0] + " --run-only start_stop")
print("\n\tExample: Run only the tests with the string 'systemd' present in them")
print("\t\t " + sys.argv[0] + " --run-only-pattern systemd")
def main(argv):
""" Run pacemaker-execd regression tests as specified by arguments """
update_path()
opts = TestOptions()
opts.build_options(argv)
- tests = Tests(opts.options['verbose'], opts.options['pacemaker-remote'],
- opts.options['timeout'], opts.options['force-wait'])
-
- tests.build_generic_tests()
- tests.build_multi_rsc_tests()
- tests.build_negative_tests()
- tests.build_custom_tests()
- tests.build_stress_tests()
-
- tests.setup_test_environment()
-
- print("Starting ...")
-
- if opts.options['list-tests']:
- tests.print_list()
- elif opts.options['show-usage']:
- opts.show_usage()
- elif opts.options['run-only-pattern'] != "":
- tests.run_tests_matching(opts.options['run-only-pattern'])
- tests.print_results()
- elif opts.options['run-only'] != "":
- tests.run_single(opts.options['run-only'])
- tests.print_results()
- else:
- tests.run_tests()
- tests.print_results()
+ # Create a temporary directory for log files (the directory will
+ # automatically be erased when done)
+ with tempfile.TemporaryDirectory(prefix="cts-exec-") as logdir:
+ tests = Tests(opts.options['verbose'], opts.options['pacemaker-remote'],
+ opts.options['timeout'], opts.options['force-wait'],
+ logdir)
+
+ tests.build_generic_tests()
+ tests.build_multi_rsc_tests()
+ tests.build_negative_tests()
+ tests.build_custom_tests()
+ tests.build_stress_tests()
+
+ tests.setup_test_environment()
+
+ print("Starting ...")
+
+ if opts.options['list-tests']:
+ tests.print_list()
+ elif opts.options['show-usage']:
+ opts.show_usage()
+ elif opts.options['run-only-pattern'] != "":
+ tests.run_tests_matching(opts.options['run-only-pattern'])
+ tests.print_results()
+ elif opts.options['run-only'] != "":
+ tests.run_single(opts.options['run-only'])
+ tests.print_results()
+ else:
+ tests.run_tests()
+ tests.print_results()
- tests.cleanup_test_environment()
- tests.exit()
+ tests.cleanup_test_environment()
+ tests.exit()
if __name__ == "__main__":
main(sys.argv)
File Metadata
Details
Attached
Mime Type
text/x-diff
Expires
Sat, Nov 23, 10:01 AM (1 d, 7 h)
Storage Engine
blob
Storage Format
Raw Data
Storage Handle
1018523
Default Alt Text
(76 KB)
Attached To
Mode
rP Pacemaker
Attached
Detach File
Event Timeline
Log In to Comment