HomeClusterLabs Projects

Fix: controld: leave xml-src attribute empty when no DC selected #2902

Description

Fix: controld: leave xml-src attribute empty when no DC selected #2902

Right after starting the cluster the DC is offline for short time,
and if you call 'crmadmin --dc_lookup' during this time, it would hang.
This change leaves the xml-src attribute that the crmadmin receives from
the pacemaker-controld empty, so that crmadmin knows the DC was not
selected.
ref: https://projects.clusterlabs.org/T735

Details

Provenance
Aleksei Burlakov <aburlakov@suse.com>Authored on Thu, Oct 17, 5:31 AM
Parents
rP33f3052b8966: Doc: ChangeLog: update for 2.1.9-rc2 release
Branches
Unknown
Tags
Unknown

Event Timeline

Aleksei Burlakov <aburlakov@suse.com> committed rP9243124df1d2: Fix: controld: leave xml-src attribute empty when no DC selected #2902 (authored by Aleksei Burlakov <aburlakov@suse.com>).Thu, Oct 17, 5:31 AM