Fix: controld: leave xml-src attribute empty when no DC selected #2902

Description

Fix: controld: leave xml-src attribute empty when no DC selected #2902

Right after starting the cluster the DC is offline for short time,
and if you call 'crmadmin --dc_lookup' during this time, it would hang.
This change leaves the xml-src attribute that the crmadmin receives from
the pacemaker-controld empty, so that crmadmin knows the DC was not
selected.
ref: https://projects.clusterlabs.org/T735

Details

Provenance
Aleksei Burlakov <aburlakov@suse.com>Authored on Sep 27 2024, 5:22 AM
Aleksei Burlako <aburlakov@suse.com>Committed on Oct 16 2024, 10:10 AM
Parents
rP8d5f0ae20cf7: Merge pull request #3700 from clumens/ctslab-patterns
Branches
Unknown
Tags
Unknown

Event Timeline

Aleksei Burlako <aburlakov@suse.com> committed rPb93f02451f65: Fix: controld: leave xml-src attribute empty when no DC selected #2902 (authored by Aleksei Burlakov <aburlakov@suse.com>).Oct 16 2024, 10:10 AM